ASTM D involves rubbing the surface of a baked film with cheesecloth soaked with MEK until failure or breakthrough of the film occurs. The type of. ronaldweinland.info Designation: D - 03 __ _ I This test method is under the jurisdiction of ASTM Committee DOI on Paint and Related. Designation: D – 03 Standard Test Method for Measuring MEK Referenced Documents ASTM Standards: D Speci?cation for.


Author:DORIAN ROKUSEK
Language:English, Spanish, French
Country:Bosnia Herzegovina
Genre:Academic & Education
Pages:253
Published (Last):26.08.2015
ISBN:636-9-41895-429-2
ePub File Size:18.57 MB
PDF File Size:11.76 MB
Distribution:Free* [*Register to download]
Downloads:43709
Uploaded by: MONNIE

D() Standard Practice for Measuring MEK Resistance of Ethyl Silicate (Inorganic) Format, Pages, Price. PDF ASTM License Agreement. Measuring MEK Resistance of Ethyl Silicate (Inorganic) Zinc-Rich Primers by Solvent Rub1. ness of Protective Coating Systems by Destructive Means5 D Practice for Assessing the Solvent Resistance of Organic Coatings Using Solvent Rubs5 3. the methyl ethyl ketone (MEK) rub. MEK Solvent Rub Resistance test (ASTM D) where a value of 4 indicates a satisfactory degree of cure for overcoating purposes. Note.

The MEK resistance of some two-component ethyl silicate zinc-rich primers has been shown to correlate well with the cure of the primer as determined by diffuse reflectance infrared spectroscopy. The technique can be used in the laboratory, field, or in the fabricating shop. Practice D is the preferred method for organic coatings. The values given in parentheses are for information only. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Rate the results in accordance with Table 1.

Also read: ASTM E155 PDF

Complete each double rub one forward and back motion in about 1 s. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every?

A number in parentheses indicates the year of last reapproval. Use this area as the control to visually show the appearance of No Effect.

Pdf astm d4752

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The values given in parentheses are for information only.

ASTM D4752 MEK Test (Zinc Test)

Performance ratings and general statistical information have been in Asym X1. If the former, record the number of rubs d the substrate is exposed.

Reagents and Materials 5. The MEK resistance of some two-component ethyl silicate zinc-rich primers has been shown to correlate well with the cure of the primer as determined by diffuse reflectance infrared spectroscopy. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, c entirely their own responsibility.

Mark a by mm 6- by 1-in. Do not allow more than 10 s to elapse before proceeding to the next steps. With the index nger at a 45 angle to the test surface, rub the rectangular test area with moderate pressure rst away from the operator and then back towards the operator. Complete each double rub one forward and back motion in about 1 s.

If the former, record the number of rubs when the substrate is exposed.

Popular Publishers

Repeat 6. Use this area as the control to visually show the appearance of No Effect. Rate the results in accordance with Table 1.

Report 7. Precision and Bias 8.

Solvent Resistance Rub Test – ASTM D4752

See Appendix X1 Goodness. Keywords 9. Using the procedure outlines in this test method, eight different operators were asked to rate, in triplicate, the methyl ethyl ketone MEK rub resistance of a particular inorganic zinc-rich primer. The primer was separately applied to multiple test panels at two different dry lm thickness ranges; 2. Separate test panels corresponding to each coating thickness category were scored after a 6-h cure period and a h cure period.

Performance ratings and general statistical information have been in Table X1.

ASTM D Measuring MEK Resistance of Ethyl Silicate (Inorganic) | Chemistry | Nature

Do not allow more than 10 s to elapse before Heavy depression in the film but no actual penetration to the substrate after 50 double rubs proceeding to the next steps. Lowards the operator. Complete each double rub one forward 7. If the former, record the number of 8. Precision and Bias rubs when the substrate is exposed. Repeat of this procedure since the rating scale is arbitrary and standard 6.

Pdf astm d4752

Use this area as the based on an arbitrary rating scale are not available. See control to visually show the appearance of No Effect. Appendix Xl "Goodness. Rate the 8. Report 9. Keywords 7. Using the combined average score of the eight operators are represented procedure ouLlines in this test method, eight different operators on each of the figures by dashed lines. The following obser- were asked to rate, in triplicate, the methyl ethyl ketone MEK vations were made through this analysis: rub resistance of a particular inorganic zinc-rich primer.