ronaldweinland.info) was developed to assist code users identify the relocated code sections. Part 1 - California Administrative Code . This part is known as the California Existing Building Code. The California Building Standards Code (Code) was developed through the outstanding. Various parts of the California Building Code are available in print in the Part 1 - Building Standards Administrative Code PDF | online.


Author:ROBT MCMICHAEL
Language:English, Spanish, Arabic
Country:Marshall Islands
Genre:Religion
Pages:535
Published (Last):23.10.2015
ISBN:889-2-76005-516-5
ePub File Size:30.60 MB
PDF File Size:19.44 MB
Distribution:Free* [*Register to download]
Downloads:40172
Uploaded by: ALLENA

View California building and construction codes in a consolidated platform. UpCodes ADA Standards Fair Housing Act Design Manual [PDF]. OSHA. o California Building Code, Volumes 1 and 2 o California Residential Code o California Electrical Code o California Mechanical Code. State Building Standards Code; Title 24 of the California Code of .. Emergency amendments to California Building Standards Code;.

From the ICC: A building code is a collection of laws regulations, ordinances or other statutory requirements adopted by a government legislative authority involved with the physical structure and healthful conditions for occupants of buildings. The purpose of a building code is to establish the minimum acceptable requirements necessary for protecting the public health, safety and welfare in the built environment. The primary application of a building code is to regulate new or proposed construction. Building codes only apply to an existing building if the building undergoes reconstruction, rehabilitation or alteration, or if the occupancy of the existing building changes to a new occupancy as defined by the building code.

California Building Energy Efficiency Standards. United States Access Board. A15 I5 v.

Pdf california building code

T Located on Geisel Floor6 KF A39 I5 for years A39 I5. If other years are needed, request them on Interlibrary loan. Org for free. New editions of the California Building Standards Code are published every three years in a triennial cycle with supplemental information published during other years. The most recent version of the code was the edition published January 1, Changes made to each edition are based off proposals made by state agencies.

Proposals are presented to the California Building Standards Commission and must provide thorough justification for proposed changes. Proposals go through multiple phases during the adoption cycle.

From Wikipedia, the free encyclopedia. A Braced Wall Line can consist only of the required Braced Wall Panels, located as described above, with the bottoms properly attached to the floor or foundation, and the tops attached to the floor above, the ceiling, or the roof. All non-engineered buildings must have Braced Wall Lines throughout, running in both directions front to back and side to side.

The maximum distance between parallel Braced Wall Lines in the City of San Bruno it varies with wind and seismic zones is 25'. The exception is that the house can have one room with a maximum 34 23 12 between braced wall panels. That room is limited under this exception to square feet. Therefore, generally, the building must be divided into boxes which are no more than 25' in either direction, and each side of each box must be a Braced Wall Line or part of a Braced Wall Line.

Remember that, if these bracing requirements are too restrictive for the design you prefer, you may submit plans with the bracing designed by a California licensed architect or engineer. Unusually Shaped Buildings: This term is used in the California Building Code to describe wood-framed buildings which require engineering. It includes a list of conditions which automatically put a building into that category.

Laterally unsupported edges of floors and roofs are one of the above-mentioned conditions. Generally, all edges of floors and roofs must be laterally supported by Braced Wall Lines.

Building pdf california code

This becomes an issue in floors with open edges such as balconies and mezzanines, and in open roofed structures such as patios and carports. An exception is made for floors and roofs which extend no more than 6' beyond a supporting Braced Wall Line.

It also becomes an issue with cantilevered roofs, whether trusses or rafters, where the roof is not directly connected to the top of the Braced Wall Line, and therefore not laterally supported by it. This latter situation can be remedied by extending the Braced Wall Panels past the ceiling up to the roof. This involves building the panels around the ceiling framing or trusses.

Angles between Braced Wall Lines other than 90 degrees is another condition which automatically requires engineering. When exceeding four feet in height, such walls shall be framed of studs having the size required for an additional story. Such walls having a stud height exceeding fourteen inches shall be braced in accordance with Table IV-C Solid blocking or plywood sheathing may be used to brace cripple walls having a stud height of fourteen inches or less.

Remember that methods 1 and 7 cannot be used to brace cripple walls in seismic zone 4. Some shearwalls required tighter nail spacing. Framing members or blocking shall be provided at the edges of all sheets in Braced Wall Panels and shearwalls. Studs in exterior walls and bearing walls must not be cut or notched more than 25 percent of their width i. Cutting or notching up to forty percent of stud width is permitted in non-bearing partitions. A bored hole not exceeding forty percent of the stud width i.

California Green Building Code

If holes up to sixty percent of the width of the stud are made, the wall studs must be doubled, and no more than two successive studs can be bored. Holes up to sixty percent of the stud width can be made in non-bearing walls without doubling i. The vertical distance between blocking shall not exceed ten feet. It is also required where a ceiling is below the top plate of the wall such as soffit ceilings, and around the edges of tubs and showers on wood floors.

Holes for pipes that pass from one floor level to another or into an attic space must have the openings firestopped with non-combustible material.

Where insulation batts are used as fireblocking between studs, they must be stapled in place. The ridge board must be not less in depth than the plumb end of the rafter. Usually a ridge board one size bigger than the rafter will meet this requirement, but at some steeper pitches, a larger size may be required.

Valley and hip rafters must be a minimum of 2X thickness and again not less in depth than the plumb end of the rafters. These ties may be the ceiling joists if parallel to the rafters or may be separate 1 x 4 minimum ties nailed to opposing rafters.

Building Department

Rafter tie spacing must not exceed four feet. Purlins must be supported by struts to bearing walls or properly designed beams. Purlins cannot be smaller than the supported rafter. Struts used to support purlins may not be smaller than 2 x 4's. Struts must not exceed eight feet unbraced, and may not be installed at slopes lower than forty-five degrees from horizontal.

Ceiling joists 2 x 6 and larger should be solidly blocked at ends unless nailed directly to rafters. Refer to the span tables for maximum allowable spans. Strongbacks are not given any credit when evaluating maximum span.

Where high and low ventilation is approximately equal, one square foot of ventilation for each three hundred square feet of attic area is required. Where high and low ventilation is not used one square foot per square feet is required.

Section of the Building Code is amended to read as follows: The roof covering assembly on any structure regulated by this code shall be as specified in Table A and as classified in section with minimum Class B fire-retardant rating.. The following guidelines pertain to its application. Gypsum wallboard shall not be installed until weather protection for the installation is provided. When practical, wallboard should be applied first to the ceilings, and then to walls. Sheets should be brought into contact but not forced into place.

Take care not to fracture the board when nailing.

Information for Designers | City of Morro Bay - Official Website

Fractures of the wallboard caused by over driving must be corrected by additional nailing. If you are using the single nailing system, the nails should be spaced 7" on center on the ceilings and 8" on center on the walls.

The double nailing system is also permitted. Approved screws may also be used to apply wallboard. Screws must be used for fastening wallboard at pocket doors. Fasteners at the top and bottom plates of vertical assemblies, or the edges and ends of horizontal assemblies perpendicular to supports, and at the wall line may be omitted except on shear-resisting elements or fire resistive assemblies.

All edges of Braced Wall Panels and firewalls must be nailed to framing. All "L" edge metal trim should be nailed every 6". Paperback corner bead is acceptable if installed in accordance with the manufacturer's instructions.

One area is the wall separating an attached garage from the living area, and the other is enclosed useable space walls and ceilings under a stairway. All gaps and penetrations must be taped or fire-caulked.